← All Advisories
Reported from OT-Advisories.com as of

Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Heap Buffer Overflow Permits Remote Code Execution

Last refreshed2026-10-15

Status: UPDATED  |  Advisory ID: CVE-2026-11822

Key Details

CVECVE-2026-11822
CVSS Score / Version
7.8 (High) / CVSS v3.1
Updated2026-10-15
CVSS Vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is local; attack complexity is low; privileges required is none; user interaction is required; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) and SQLite sqlite
Classified as
CWE-122 (Heap-based Buffer Overflow)
Exploitation prediction (EPSS)
0.29% probability of exploitation in the next 30 days (21% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
SiemensRUGGEDCOM CROSSBOW Station Access Controller (SAC)
SQLitesqlite
SubsystemsGeneral OT
SectorsMultiple

What to Know

SQLite before 3.53.2 contains memory corruption vulnerabilities in the FTS5 full-text search extension that allow attackers to cause process crashes, memory exhaustion, or arbitrary code execution by supplying a crafted database with malformed FTS5 page data. Attackers can trigger an out-of-bounds read in fts5LeafSeek() via an attacker-controlled loop bound and a heap buffer overflow write in fts5ChunkIterate() through a crafted continuation page causing an integer underflow, exploitable when an FTS5 MATCH query is executed against the malicious database. (NVD)

What to Do

Monitor Siemens's and SQLite's web pages for any future patch releases.

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-11822
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-11822