← All Advisories
Reported from OT-Advisories.com as of

Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) Heap Buffer Overflow Permits Remote Code Execution

Last refreshed2026-10-15

Status: UPDATED  |  Advisory ID: CVE-2026-11824

Key Details

CVECVE-2026-11824
CVSS Score / Version
7.8 (High) / CVSS v3.1
Updated2026-10-15
CVSS Vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS Prose
attack vector is local; attack complexity is low; privileges required is none; user interaction is required; scope is unchanged; confidentiality impact is high; integrity impact is high; availability impact is high.
Affected products
Siemens RUGGEDCOM CROSSBOW Station Access Controller (SAC) and SQLite sqlite
Classified as
CWE-122 (Heap-based Buffer Overflow)
Exploitation prediction (EPSS)
0.18% probability of exploitation in the next 30 days (7% percentile) -- FIRST.org's EPSS model.

Affected Products, Subsystems & Sectors

VendorProductAffected VersionsPatch Status
SiemensRUGGEDCOM CROSSBOW Station Access Controller (SAC)
SQLitesqlite
SubsystemsGeneral OT
SectorsMultiple

What to Know

SQLite before 3.53.2 contains a heap-based buffer overflow vulnerability in the FTS5 full-text search extension that allows attackers to cause a crash or execute arbitrary code by supplying a crafted database with malicious continuation page metadata specifying a szLeaf value smaller than 4. Attackers can trigger an integer underflow in fts5ChunkIterate() causing an inflated remaining byte count during FTS5 MATCH query processing, leading to a heap buffer overflow of attacker-controlled data in applications compiled with SQLITE_ENABLE_FTS5. (NVD)

What to Do

Monitor Siemens's and SQLite's web pages for any future patch releases.

References

SourceReference
NVDhttps://nvd.nist.gov/vuln/detail/CVE-2026-11824
CVEhttps://www.cve.org/CVERecord?id=CVE-2026-11824
Report compilation © 2026 OT-Advisories.com  ·  CC BY 4.0  ·  Source materials remain the property of their respective publishers as cited.